Nuevo

Carrier I-vu Uc Open Opn-uc Open Controller

Este producto no está disponible por el momento.

Características del producto

Características principales

Marca
Carrier
Modelo
OPN-UC

Descripción

Stock propio, entrega inmediata

OPN-UC
Controlador de propósito general
El controlador programable universal proporciona control auxiliar del edificio para interactuar con iluminación, ventiladores, bombas y otros equipos HVAC. 6 entradas / 5 salidas.
El controlador UC Open proporciona control auxiliar del edificio para interactuar con iluminación, ventiladores, bombas y otros equipos HVAC. Los programas de control diseñados en fábrica de UC Open proporcionan una integración de edificios sencilla para aplicaciones comerciales con capacidad de 11 puntos de E / S.

BACNet Support Advanced application controller (B-AAC), as defined in BACNet 135-2001 Annex L
Communication Ports BACNet Port: EIA-485 port for BACnet MS/TP communications (9600 bps, 19.2 kbps, 38.4 kbps, and 76.8 kbps)
Local Access port: For system start-up and troubleshooting (115.2 kbps)
Rnet port: For connecting Carrier communicating room sensors and Carrier's touchscreen user interface
Inputs 6 inputs: Configurable for thermistor or dry contact. Inputs 1 and 2 are also configurable for 0-5 VDC sensors. AIs have 12 bit A/D resolution.
Outputs 5 binary outputs: Relay contacts rated at 1 A max @ 24 VAC/VDC, configured normally open.
Protection Incoming power and network connections are protected by non-replaceable internal solidstate polyswitches that reset themselves when the condition that causes a fault returns to normal. The power, network, input, and output connections are also protected against voltage transient and surge events.
Real Time Clock Battery-backed real time clock keeps track of time in event of power failure.
Battery 10-year Lithium CR2032 battery provides a minimum of 10,000 hours of trend data & time retention during power outages.
Status Indicators LED status indicators for communications, run status, error, and power.
Controller Addressing Rotary DIP switches set BACnet MS/TP MAC address of controller.
Listed By UL-916 (PAZX), cUL-916 (PAZX7)FCC Part 15-Subpart B- Class A, CE EN50082-1997
Environmental Operating Range Operating: 0° to 140°F (-18° to 60°C), 10-90% relative humidity, non-condensing
Storage: -24°F to 140°F (-30° to 60°C), 10-90% relative humidity, non-condensing
Power Requirements 24VAC +/- 10%, 50-60Hz
18VA power consumption
26VDC (25V min, 30V max
Single Class 2 source only, 100VA or less
Dimensions Length: 5-5/8” (14.3cm)
Width: 5-1/8” (13 cm)
Depth: 2” (5.1 cm)
Weight: 0.44 lbs. (0.20 kg)